Omega International Technology, Inc.

INDEX

ThruVU System
Pipeline Scanner
Cassette System


Tangential CT


AutomatedFilmless Radiography
Weld Inspection
Food Scanner


Detector Array


Services


R/D

Food Inspection/Foreign Object Detection System

Minimum Sensitivity:    0.5 mm to 1.0 mm steel at 10 meters/minute conveyor speed.

System Description:
Detectors:                                        Linear Array of individual solid state detectors
Number of Channels                        80
Type                                                 High Z Scintillator coupled to photodiode
Pitch                                                 3.81 mm
Total Length of Array                       304.8 mm (12")
Response time                                   ~ 1 msec
Analog-to-Digital Conversion           12 Bit (16 Bit possible); 100 kHz rate
X-Ray System:                                  Hi Frequency (20-50 KHz) DC X-Ray Source
Maximum Energy                             100 kV (two supplies +50 kV and -50 kV
Maximum Current                            1 mA
X-Ray Tube Configuration                Dual Ended (+/- 50 kV)
Shielding                                           Shielded to meet 21 CFR regulations
X-Ray Fan Angle                               ~ 45 degrees
Computer System:                             Complete Pentium based desktop PC
Software System:                               Complete Automated Data Collection and Analysis Routine
Data Collection Software:                   Custom data collection routine
Data Analysis Software                       Custom On-line Analysis routine
Reject Signal: The data collection and data analysis routines work concurrently to collect and analyze
the data from the detector array to detect foreign objects.  When a foreign object is detected in the
detector data then the computer generates a TTL signal in real-time. This TTL pulse is available to
customer for initiating any type of reject mechanism.

System Components:
Detector System
               
80 Channel Detector Array with shielding and collimation
                  + 12V, -12V, +5V Power Supply system for Detector Array
                   15 Conductor Cable (3 meter long) for Detector Array
                   50 conductor cable for Detector Signal to ADC Board
Analog-to-Digital Board:
                   12 or 16 Bit commercial ADC Board with 100,000/second maximum data rate capability
                   The ADC Board will be located inside the computer system.
X-Ray System:
                  + 50 kV High Voltage Supply
                  - 50 kV High Voltage Supply
                   2 High Voltage Cables (1 meter long)
                   100 kV- 1 mA X-ray Tube (shielded)
                 Low Voltage DC Power Supply for HV supplies
                    Interconnection Cables
                    DC Voltmeters for kV and mA
Computer System:
    Pentium Computer with hard, floppy and CD ROM drives, mouse, key board and  SVGA monitor.

Company Profile

Directory

E-mail
Omegait@mc.net

LINKS

Omega International Technology, Inc.
  460 Wegner Road, Lakemoor, IL 60050-8653, U.S.A.
  Phone: (815)-344-5455         FAX: (815)-344-3336
 
E-Mail: omegait@mc.net     Web Site: http://user.mc.net/omegait

Previous Page                                       